The Range:
The Parker 890 Range comes in 4 sub-options:
890SD – Standalone Drive Module
890CD – Multi-Axis Drive Module (Common DC Bus)
890CS – Multi-Axis Power Supply Module (Common DC Bus)
890CA – Common Bus Power Adaptor Module
Frame Sizes:
Below are the power ratings for the different options and frame sizes. TOF = Top of Frame.
890SD
3PH, 230V
Frame B (0.55, 1.1, 1.5, 2.2, 4) kW [TOF: 890SD-232165B0-B00-1A000]
Frame C (5.5, 7.5) kW [TOF: 890SD-232300C0-B00-1A000]
3PH, 400/460V
Frame E (37, 45) kW [TOF: 890SD-432870E0-B00-1A000]
Frame F (55, 75, 90) kW [TOF: 890SD-433156F1-B00-1A000 / 890SD-433156F2-B00-1A000]
Frame G (110, 132, 160, 180) kW [TOF: 890SD-433361G1-B00-1A000 / 890SD-433361G2-B00-1A000]
Frame H (200, 220, 250, 280) kW [TOF: 890SD-433520H1-B00-1A000 / 890SD-433520H2-B00-1A000]
Frame J (315) kW [TOF: 890SD-433590J1-B00-1A000 / 890SD-433590J2-B00-1A000]
3PH, 400/500V
Frame B (0.55, 1.1, 1.5, 2.2, 4, 5.5, 7.5) kW [TOF: 890SD-532160B0-B00-1A000]
Frame C (11, 15) kW [TOF: 890SD-532300C0-B00-1A000]
Frame D (18.5, 22, 30) kW [TOF: 890SD-532590D0-B00-1A000]
Frame E (37, 45) kW [TOF: 890SD-532870E0-B00-1A000]
Frame F (55, 75, 90) kW [TOF: 890SD-533156F1-B00-1A000 / 890SD-533156F2-B00-1A000]
Frame G (110, 132, 160, 180) kW [TOF: 890SD-433361G1-B00-1A000 / 890SD-433361G2-B00-1A000]
Frame H (200, 220, 250, 280) kW [TOF: 890SD-433520H1-B00-1A000 / 890SD-433520H2-B00-1A000]
Frame J (315) kW [TOF: 890SD-433590J1-B00-1A000 / 890SD-433590J2-B00-1A000]
890CD
320V DC
Frame B (0.55, 1.1, 1.5, 2.2, 4) kW [TOF: 890CD-232165B0-000-1A000]
Frame C (5.5, 7.5) kW [TOF: 890CD-232300C0-000-1A000]
560/650V DC
Frame E (37, 45) kW [TOF: 890CD-432870E0-000-1A000]
Frame F (55, 75, 90) kW [TOF: 890CD-433180F1-000-1A000 / 890CD-433180F2-000-1A000]
Frame G (110, 132, 160, 180) kW [TOF: 890CD-433361G1-000-1A000 / 890CD-433361G2-000-1A000]
Frame H (220, 250, 280) kW [TOF: 890CD-433520H1-000-1A000 / 890CD-433520H2-000-1A000]
Frame J (315) kW [TOF: 890CD-433590J1-000-1A000 / 890CD-433590J2-000-1A000]
560/705V DC
Frame B (0.55, 1.1, 1.5, 2.2, 4, 5.5, 7.5) kW [TOF: 890CD-532160B0-000-1A000]
Frame C (11, 15) kW [TOF: 890CD-532300C0-000-1A000]
Frame D (18.5, 22, 30) kW [TOF: 890CD-532590D0-000-1A000]
Frame E (37, 45) kW [TOF: 890CD-532870E0-000-1A000]
Frame F (55, 75, 90) kW [TOF: 890CD-533156F1-000-1A000 / 890CD-533156F2-000-1A000]
890CS
Frame B (32, 54) kW [TOF: 890CS-532540B0-B00-U]
Frame D (108, 162) kW [TOF: 890CS-533162D0-B00-U]
890CA
Frame B (50, 80) kW [TOF: 890CA-532800B0-000-U]
Frame Dimensions:
Frame B (72(W) x 434(H) x 258.5(D) mm) – 6kg
Frame C (116(W) x 434(H) x 258.5(D) mm) – 7kg
Frame D (160(W) x 434(H) x 258.5(D) mm) – 15kg
Frame E (257(W) x 668(H) x 312(D) mm) – 45kg
Frame F (257(W) x 720(H) x 349(D) mm) – 62kg
Frame G (456(W) x 1042(H) x 465(D) mm) – 108kg
Frame H (572(W) x 1177(H) x 465(D) mm) – 138kg
Frame J (677(W) x 1288(H) x 465(D) mm) – 176kg
Options:
There are a number of language options available for each drive. All drives must now be sold with Keypads. There are a number of purchasable additional options for the 890SD and 890CD listed below:
Note: the last block of the part number contains 5 digits, the last 3 of which denote the purchasable
options. These will be referred to as option X, Y, and Z (XYZ).
Option X
0 – No Keypad
1 – SinCos Encoder [8902-E1-00]
3 – Incr. Quadr. Encoder [8902-EQ-00]
5 – Resolver [8902-RE-00]
6 – Resolver Repeater [8902-RR-00]
7 – Mark Registration [8902-M1-00]
L – Line Synchronisation [8902-LS-00]
Option Y
0 – None
N – CanOpen Comms [8903-CB-00]
C – ControlNet Comms [8903-CN-00]
D – DeviceNet [8903-DN-00]
H – EtherNet/IP [8903-IP-00]
T – Modbus TCP/IP [8903-IM-00]
P – Profibus Comms [8903-PB-00]
7 – Mark Registration [8903-M1-00]
S – RS485 [8903-RS-00]
K – EtherCAT [8903-CT-00]
R – Analogue Input Option [8903-AI-00]
E – Encoder Option [8903-EP-00]
Y – ProfiNet Comms [8903-PN-00]
Option Z
0 – None
A – Firewire 1394A [8903-FA-00]
X – Special Peer-Peer Protocol [8903-SP-00]
R – Analogue Input Option [8903-AI-00]
E – Encoder Option [8903-EP-00]
Y – LinkNET Comms [8903-LN-83-00]
Parker 890 Standalone 3PH, 400/500V 1.1kW 890SD-531350B0-B00-1A000
Part Code
890SD-531350B0-B00-1A000
Commodity Code
85371091
Legacy Part Code
890SD/5/0003B/B/00/A/UK/00/00/00/00/00
Manufacturer
Parker Hannifin
£995.15
Available on backorder
for Lead Time
Ask about our lead times for backorders
Get in touch and we'll get back to you about the time it will take to get this product to you.
Supplied with 12 month manufacturer’s warranty
Need this repaired?
Need this repaired?
Give us a call and send it our way. Our engineers can restore it or offer a replacement so your systems run better than before - and with 12 months warranty too.
Need this installed?
Need this installed?
We can travel to any site in the UK or abroad to install your product and can configure it to run optimally with your system.
Need some support?
Need some support?
Our expert engineers are just on the other end of a phone. Get in touch to get your questions answered.
Looking for a quote?
Looking for a quote?
Tell us what your requirements are and our experienced sales team will source a solution to fit your budget.
- Parker 890 - Product Catalog Download
- Parker 890 - DSE 890 Software Product Manual Download
- Parker 890 - Frame Size Guide Download
- Parker 890 - Full Product Manual (Frame B-D) Download
- Parker 890 - Full Product Manual (Frame E-F) Download
- Parker 890 - Full Product Manual (Frame G-J) Download
- Parker 890 - Full Product Manual (Frame K) Download
- Parker 890 - Quickstart Guide (CA) Download
- Parker 890 - Quickstart Guide (CS _ CD Frame B-D) Download
- Parker 890 - Quickstart Guide (CS _ CD Frame E-F) Download
- Parker 890 - Quickstart Guide (SD) Download
- Parker 890 - Product Code Breakdown Download
- DSE Lite Configuration Tool Download
- Download
- Country of Origin Germany
- Commodity Code 85371091
- Volumetric Weight
- Weight (Kg) 6
- Dimensions (mm) 72 x 434 x 259
Get your free download by completing this form
Download support product manuals, technical drawings and software or use our drive configurator to establish the spec of your units. If you don’t find what you’re looking for here, answers are just a phone call away.
"*" indicates required fields