890 Common Bus Drive – 560/705VDC – 22kW, Frame D – Universal Auxiliary – No Brake Fitted – No Special Options – Advanced – English (50Hz) – None – None – None

Part Code

890CD-532450D0-000-1A000

Commodity Code

85044090 

Legacy Part No

890CD/5/0045D/N/00/A/UK/00/00/00/00/00

Manufacturer

Parker Hannifin

890 Common Bus Drive – 560/705VDC – 22kW, Frame D – Universal Auxiliary – No Brake Fitted – No Special Options – Advanced – English (50Hz) – None – None – None

£1,823.49

Buy New

Available on backorder

£1823.49ex VAT
List price - £3,039.15 ex VAT

Supplied with 12 month manufacturer’s warranty

SKU: 890CD-532450D0-000-1A000 Categories: , ,
Product Details
Features
Downloads & Resources
Delivery
Arrow
  • Drive Type AC Inverter Drive
  • Manufacturer Parker Hannifin
  • Product Range 890CD
  • Status New
  • Commodity Code 85044090 
  • Country of Origin Germany
  • Frame Size D
  • Dimensions (mm) 160 x 434 x 259
  • Weight (Kg) 15
  • Top of Frame 890CD-532590D0-000-1A000
  • Product Range 890CD
  • Phase 3PH
  • Supply 560/705V DC
  • Power 22kW
  • Keypad Yes
  • IP Rating IP20
  • Open Loop Yes
  • Sensorless Vector Yes
  • Closed-Loop Vector Yes
  • Active Front End Yes
  • Permanent Magnet AC Yes
  • Common Supply Yes
  • Brake Switch No
  • EMC Filter No
  • Mounting Panel Mount
  • Auxillary Universal
  • Regen No
  • Special 1 Advanced
    • Country of Origin Germany
    • Commodity Code 85044090 
    • Weight (Kg) 15
    • Dimensions (mm) 160 x 434 x 259

    The Range:
    The Parker 890 Range comes in 4 sub-options:
    890SD – Standalone Drive Module
    890CD – Multi-Axis Drive Module (Common DC Bus)
    890CS – Multi-Axis Power Supply Module (Common DC Bus)
    890CA – Common Bus Power Adaptor Module

    Frame Sizes:
    Below are the power ratings for the different options and frame sizes. TOF = Top of Frame.

    890SD

    3PH, 230V
    Frame B (0.55, 1.1, 1.5, 2.2, 4) kW [TOF: 890SD-232165B0-B00-1A000]
    Frame C (5.5, 7.5) kW [TOF: 890SD-232300C0-B00-1A000]

    3PH, 400/460V
    Frame E (37, 45) kW [TOF: 890SD-432870E0-B00-1A000]
    Frame F (55, 75, 90) kW [TOF: 890SD-433156F1-B00-1A000 / 890SD-433156F2-B00-1A000]
    Frame G (110, 132, 160, 180) kW [TOF: 890SD-433361G1-B00-1A000 / 890SD-433361G2-B00-1A000]
    Frame H (200, 220, 250, 280) kW [TOF: 890SD-433520H1-B00-1A000 / 890SD-433520H2-B00-1A000]
    Frame J (315) kW [TOF: 890SD-433590J1-B00-1A000 / 890SD-433590J2-B00-1A000]

    3PH, 400/500V
    Frame B (0.55, 1.1, 1.5, 2.2, 4, 5.5, 7.5) kW [TOF: 890SD-532160B0-B00-1A000]
    Frame C (11, 15) kW [TOF: 890SD-532300C0-B00-1A000]
    Frame D (18.5, 22, 30) kW [TOF: 890SD-532590D0-B00-1A000]
    Frame E (37, 45) kW [TOF: 890SD-532870E0-B00-1A000]
    Frame F (55, 75, 90) kW [TOF: 890SD-533156F1-B00-1A000 / 890SD-533156F2-B00-1A000]
    Frame G (110, 132, 160, 180) kW [TOF: 890SD-433361G1-B00-1A000 / 890SD-433361G2-B00-1A000]
    Frame H (200, 220, 250, 280) kW [TOF: 890SD-433520H1-B00-1A000 / 890SD-433520H2-B00-1A000]
    Frame J (315) kW [TOF: 890SD-433590J1-B00-1A000 / 890SD-433590J2-B00-1A000]

    890CD

    320V DC
    Frame B (0.55, 1.1, 1.5, 2.2, 4) kW [TOF: 890CD-232165B0-000-1A000]
    Frame C (5.5, 7.5) kW [TOF: 890CD-232300C0-000-1A000]

    560/650V DC
    Frame E (37, 45) kW [TOF: 890CD-432870E0-000-1A000]
    Frame F (55, 75, 90) kW [TOF: 890CD-433180F1-000-1A000 / 890CD-433180F2-000-1A000]
    Frame G (110, 132, 160, 180) kW [TOF: 890CD-433361G1-000-1A000 / 890CD-433361G2-000-1A000]
    Frame H (220, 250, 280) kW [TOF: 890CD-433520H1-000-1A000 / 890CD-433520H2-000-1A000]
    Frame J (315) kW [TOF: 890CD-433590J1-000-1A000 / 890CD-433590J2-000-1A000]

    560/705V DC
    Frame B (0.55, 1.1, 1.5, 2.2, 4, 5.5, 7.5) kW [TOF: 890CD-532160B0-000-1A000]
    Frame C (11, 15) kW [TOF: 890CD-532300C0-000-1A000]
    Frame D (18.5, 22, 30) kW [TOF: 890CD-532590D0-000-1A000]
    Frame E (37, 45) kW [TOF: 890CD-532870E0-000-1A000]
    Frame F (55, 75, 90) kW [TOF: 890CD-533156F1-000-1A000 / 890CD-533156F2-000-1A000]

    890CS
    Frame B (32, 54) kW [TOF: 890CS-532540B0-B00-U]
    Frame D (108, 162) kW [TOF: 890CS-533162D0-B00-U]

    890CA
    Frame B (50, 80) kW [TOF: 890CA-532800B0-000-U]

    Frame Dimensions:
    Frame B (72(W) x 434(H) x 258.5(D) mm) – 6kg
    Frame C (116(W) x 434(H) x 258.5(D) mm) – 7kg
    Frame D (160(W) x 434(H) x 258.5(D) mm) – 15kg
    Frame E (257(W) x 668(H) x 312(D) mm) – 45kg
    Frame F (257(W) x 720(H) x 349(D) mm) – 62kg
    Frame G (456(W) x 1042(H) x 465(D) mm) – 108kg
    Frame H (572(W) x 1177(H) x 465(D) mm) – 138kg
    Frame J (677(W) x 1288(H) x 465(D) mm) – 176kg

    Options:
    There are a number of language options available for each drive. All drives must now be sold with Keypads. There are a number of purchasable additional options for the 890SD and 890CD listed below:

    Note: the last block of the part number contains 5 digits, the last 3 of which denote the purchasable
    options. These will be referred to as option X, Y, and Z (XYZ).

    Option X
    0 – No Keypad
    1 – SinCos Encoder [8902-E1-00]
    3 – Incr. Quadr. Encoder [8902-EQ-00]
    5 – Resolver [8902-RE-00]
    6 – Resolver Repeater [8902-RR-00]
    7 – Mark Registration [8902-M1-00]
    L – Line Synchronisation [8902-LS-00]

    Option Y
    0 – None
    N – CanOpen Comms [8903-CB-00]
    C – ControlNet Comms [8903-CN-00]
    D – DeviceNet [8903-DN-00]
    H – EtherNet/IP [8903-IP-00]
    T – Modbus TCP/IP [8903-IM-00]
    P – Profibus Comms [8903-PB-00]
    7 – Mark Registration [8903-M1-00]
    S – RS485 [8903-RS-00]
    K – EtherCAT [8903-CT-00]
    R – Analogue Input Option [8903-AI-00]
    E – Encoder Option [8903-EP-00]
    Y – ProfiNet Comms [8903-PN-00]

    Option Z
    0 – None
    A – Firewire 1394A [8903-FA-00]
    X – Special Peer-Peer Protocol [8903-SP-00]
    R – Analogue Input Option [8903-AI-00]
    E – Encoder Option [8903-EP-00]
    Y – LinkNET Comms [8903-LN-83-00]

    The SDS Difference

    Need this repaired?

    Give us a call and send it our way. Our engineers can restore it or offer a replacement so your systems run better than before - and with 12 months warranty too.

    Need this repaired?

    Give us a call and send it our way. Our engineers can restore it or offer a replacement so your systems run better than before - and with 12 months warranty too.

    Need this installed?

    We can travel to any site in the UK or abroad to install your product and can configure it to run optimally with your system.

    Need this installed?

    We can travel to any site in the UK or abroad to install your product and can configure it to run optimally with your system.

    Need some support?

    Our expert engineers are just on the other end of a phone. Get in touch to get your questions answered.

    Need some support?

    Our expert engineers are just on the other end of a phone. Get in touch to get your questions answered.

    Looking for a quote?

    Tell us what your requirements are and our experienced sales team will source a solution to fit your budget.

    Looking for a quote?

    Tell us what your requirements are and our experienced sales team will source a solution to fit your budget.